PO Box 490, Ravenswood, WV 26164
304-273-5356 Fax 304-273-2531
valtronics@valtronicsinc.com

Route 68 North
Murraysville, West Virginia 26164
www.valtronicsinc.net

MUSTANG ® LNG Gas Sample Vaporization
and Conditioning System

New Electrical/Process Technology from Valtronics

  • Enhanced sample quality through
    controlled gas vaporization and re-mixing

  • Continuous gas flow design and
    elimination of post-vaporization
    hydrocarbon liquid dropout mean
    accurate and reliable BTU
    measurements by your GC

  • Installs at the offloading pipeline and
    other terminal measurement locations

  • Software package for operating,
    monitoring, trending and reporting functions

  • The Mustang ® LNG Sample Vaporizer is a patented design to vaporize LNG and provide a fresh sample to a continuous online gas chromatograph. This is accomplished through 4 stages within the Mustang ® LNG Sample Vaporizer.

    Stage 1

    The vaporizer is avialable in either a multi path or single path design to vaporize LNG and send sample
    to the accumulator for restructuring

    Stage 2

    The accumulator cylinder is designed with a special impingement tube designed to allow the gas
    components to return to their original composition.

    Stage 3

    A pre and post heated pressure regulator designed to prevent hydrocarbon dew point dropout and reduce
    sample pressure which is then delivered to the chromatograph thru a heated sample tube.

    Stage 4

    vapor Return By Pass Flow Control System

    Soft View Monitor Program

    The Mustang ® LNG Sample Vaporizer Software supplies a monitor program that is
    Windows driven, 2000 or XP.

    1. Software provides:
          A. Vaporizer & Gas Chromatograph Set Point Operation and Monitor Screens
          B. History & Real Time Date Trending
          C. Report Spread Sheet providing:
                1. Vaporizer Operation and Gas Component Data
                2. Vaporizer Controller Monitor
                3. LNG Load Definition Sheet
                4. LNG Load Report with Averages per ship

    Accuracies & Repeatability

    The Mustang ® LNG Sample Vaporizer Systen assures the sample to the chromatograph is
    in a stable composition in order for the chromatograph to meet its stated accuracy.


    For more information contact

    Valtronics, Inc.
    PO Box 490
    Ravenswood, WV 26164
    1-304-273-5356
    Fax: 1-304-273-2531
    Email: valtronics@valtronicsinc.com
    www.valronicsinc.com
    Copyright Valtronics, Inc. 2008